Rinnai tankless water heater error codes

Rinnai is one of the most widely installed tankless water heater brands in the US. Its diagnostic codes are grouped by series generation — SENSEI RX/CX, SENSEI, and the older non-SENSEI models — and the same two-digit number can point at a different component depending on which generation is on the wall. Every code below is read from Rinnai's own diagnostic documentation for the exact series, not averaged across the brand.

Pick your series below — Rinnai code meanings are documented per series, because the same number can point to a different fault on a different generation.

Codes documented on more than one Rinnai series

Pick a number to see what it means on each series side by side — useful when you know the code but not the generation.

Not sure which series you own? The model-number decoder matches the number on your rating label to the right table.

All Rinnai codes in one table

Code Series Error Verdict
02 Non-SENSEI No burner operation during freeze protection Call a pro
03 Non-SENSEI Power interruption during bath fill DIY fix
05 Non-SENSEI Bypass flow control device fault Part replacement
10 Non-SENSEI Air supply or exhaust blockage Call a pro
11 Non-SENSEI No ignition Call a pro
12 Non-SENSEI Flame failure Call a pro
14 Non-SENSEI Overheat switch or thermal fuse tripped Call a pro
16 Non-SENSEI Outlet water temperature too high Call a pro
19 Non-SENSEI Electrical grounding fault Call a pro
25 Non-SENSEI Condensate pump fault or blocked condensate drain DIY fix
31 Non-SENSEI Burner thermocouple out of range Call a pro
32 Non-SENSEI Outgoing water temperature thermistor fault Part replacement
33 Non-SENSEI Heat exchanger thermistor fault Part replacement
34 Non-SENSEI Combustion air temperature thermistor fault Call a pro
38 Non-SENSEI Exhaust gas temperature sensor fault Call a pro
41 Non-SENSEI Freeze protection sensor fault Part replacement
51 Non-SENSEI Inlet water temperature thermistor fault Part replacement
52 Non-SENSEI Modulating solenoid valve (POV) signal fault Call a pro
54 Non-SENSEI Exhaust gas temperature too high Call a pro
57 Non-SENSEI Burner overheat bi-metal switch tripped Call a pro
58 Non-SENSEI Secondary heat exchanger switch tripped Call a pro
61 Non-SENSEI Combustion fan motor fault Call a pro
63 Non-SENSEI Recirculation low flow DIY fix
65 Non-SENSEI Water flow control valve fault Part replacement
70 Non-SENSEI PC board fault Call a pro
71 Non-SENSEI SV0-SV3 solenoid valve fault Call a pro
72 Non-SENSEI Flame rod fault Call a pro
73 Non-SENSEI Burner thermocouple fault Call a pro
79 Non-SENSEI Water leakage detected Call a pro
FF Non-SENSEI Maintenance performed marker DIY fix
LC Non-SENSEI Scale build-up in the heat exchanger DIY fix
05 RH180 Hybrid Air screen restricted DIY fix
07 RH180 Hybrid Circulation flow below 2.1 GPM DIY fix
10 RH180 Hybrid Air supply or exhaust blockage Call a pro
11 RH180 Hybrid No ignition Call a pro
12 RH180 Hybrid No flame Call a pro
13 RH180 Hybrid Combustion fault Call a pro
14 RH180 Hybrid Thermal fuse triggered Call a pro
16 RH180 Hybrid Over temperature warning Call a pro
30 RH180 Hybrid Flammable vapour sensor fault Call a pro
31 RH180 Hybrid Burner sensor fault Call a pro
32 RH180 Hybrid Heat exchanger outgoing temperature sensor fault Call a pro
35 RH180 Hybrid Tank temperature sensor fault Call a pro
38 RH180 Hybrid Carbon monoxide or flammable vapour sensor fault Call a pro
52 RH180 Hybrid Modulating solenoid valve signal fault Call a pro
61 RH180 Hybrid Combustion fan fault Call a pro
63 RH180 Hybrid Circulation flow below 1.3 GPM DIY fix
71 RH180 Hybrid Solenoid valve circuit fault Call a pro
72 RH180 Hybrid Flame sensing device fault Call a pro
73 RH180 Hybrid Burner sensor circuit fault Call a pro
FE RH180 Hybrid Flammable vapours detected Emergency — stop
03 SENSEI Power interruption during bath fill DIY fix
05 SENSEI Bypass flow control device fault Part replacement
10 SENSEI Air supply or exhaust blocked, or the condensate trap is full Call a pro
11 SENSEI No ignition Call a pro
12 SENSEI Flame failure Call a pro
14 SENSEI Overheat sensor or thermal fuse tripped Call a pro
15 SENSEI Venturi control fault Call a pro
16 SENSEI Outlet water temperature too high Call a pro
17 SENSEI Venturi blockage Call a pro
19 SENSEI Electrical grounding fault Call a pro
21 SENSEI Data transfer error Call a pro
25 SENSEI Condensate pump fault or blocked condensate drain DIY fix
32 SENSEI Outgoing water temperature thermistor fault Part replacement
33 SENSEI Heat exchanger thermistor fault Part replacement
38 SENSEI Exhaust gas temperature sensor fault Call a pro
41 SENSEI Freeze protection sensor fault Part replacement
51 SENSEI Inlet water temperature thermistor fault Part replacement
52 SENSEI Gas valve fault Call a pro
54 SENSEI Exhaust gas temperature too high Call a pro
61 SENSEI Combustion fan motor fault Call a pro
63 SENSEI Recirculation low flow DIY fix
65 SENSEI Water flow control valve fault Part replacement
70 SENSEI PC board fault Call a pro
71 SENSEI Gas solenoid valve fault Call a pro
72 SENSEI Flame rod fault Call a pro
FF SENSEI Maintenance performed marker DIY fix
SS SENSEI Service soon reminder DIY fix
03 SENSEI RX Power interruption during bath fill DIY fix
10 SENSEI RX Air supply or exhaust blocked, or the condensate trap is full Call a pro
11 SENSEI RX No ignition Call a pro
12 SENSEI RX Flame failure Call a pro
14 SENSEI RX Overheat sensor or thermal fuse tripped Call a pro
15 SENSEI RX Venturi control fault Call a pro
16 SENSEI RX Outlet water temperature too high Call a pro
17 SENSEI RX Venturi blockage Call a pro
18 SENSEI RX Gas valve adjustment limit reached Call a pro
19 SENSEI RX Electrical grounding fault Call a pro
21 SENSEI RX Data transfer error Call a pro
22 SENSEI RX Gas valve adjustment fault Call a pro
25 SENSEI RX Condensate pump fault or blocked condensate drain DIY fix
32 SENSEI RX Outgoing water temperature thermistor fault Part replacement
33 SENSEI RX Heat exchanger thermistor fault Part replacement
34 SENSEI RX Lime detecting thermistor fault Part replacement
38 SENSEI RX Exhaust gas temperature sensor fault Call a pro
41 SENSEI RX Freeze protection sensor fault Part replacement
51 SENSEI RX Inlet water temperature thermistor fault Part replacement
52 SENSEI RX Gas valve fault Call a pro
54 SENSEI RX Exhaust gas temperature too high Call a pro
61 SENSEI RX Combustion fan motor fault Call a pro
63 SENSEI RX Recirculation low flow DIY fix
65 SENSEI RX Water flow control valve fault Part replacement
66 SENSEI RX Bypass flow servo fault Part replacement
70 SENSEI RX PC board fault Call a pro
71 SENSEI RX Gas solenoid valve fault Call a pro
72 SENSEI RX Flame rod fault Call a pro
FF SENSEI RX Maintenance performed marker DIY fix
LC SENSEI RX Scale build-up lockout DIY fix
SS SENSEI RX Service soon reminder DIY fix

Each code links to a full page: what the manual says for that exact series, the likely fix, and what it should cost.