Rinnai SENSEI error codes

The SENSEI is the condensing generation Rinnai sold before the SENSEI RX, and it is on a very large number of US walls — RU models, RUR and RSC with a recirculation pump, indoor (i) and outdoor (e). Its code table is not the RX table. It has code 05 for the bypass flow control device, where the RX moved that fault to code 66; it has no LC scale lockout at all, so scale surfaces only as the SS service reminder; and codes 18, 22 and 34 do not exist on it. Gas type is set by a physical orifice in the gas valve (red for propane, blue for natural gas) rather than by a software parameter, and the reset sequences on the PC board are different too.

Models covered: RU199i / RU199e (REU-N3237FF-US / REU-N3237W-US), RU180i / RU180e (REU-N2934FF-US / REU-N2934W-US), RU160i / RU160e (REU-N2530FF-US / REU-N2530W-US), RU130i / RU130e (REU-N2024FF-US / REU-N2024W-US), RUR199i / RUR199e (REU-NP3237FF-US / REU-NP3237W-US), RUR160i / RUR160e (REU-NP2530FF-US / REU-NP2530W-US), RSC199i / RSC199e (REU-NP3237FF-US(A) / REU-NP3237W-US(A)), RSC160i / RSC160e (REU-NP2530FF-US(A) / REU-NP2530W-US(A))

Not your models? Check the model-number decoder before you read the table below — the code numbers repeat across series and the meanings do not.

Code Error Verdict
03 Power interruption during bath fill DIY fix
05 Bypass flow control device fault Part replacement
10 Air supply or exhaust blocked, or the condensate trap is full Call a pro
11 No ignition Call a pro
12 Flame failure Call a pro
14 Overheat sensor or thermal fuse tripped Call a pro
15 Venturi control fault Call a pro
16 Outlet water temperature too high Call a pro
17 Venturi blockage Call a pro
19 Electrical grounding fault Call a pro
21 Data transfer error Call a pro
25 Condensate pump fault or blocked condensate drain DIY fix
32 Outgoing water temperature thermistor fault Part replacement
33 Heat exchanger thermistor fault Part replacement
38 Exhaust gas temperature sensor fault Call a pro
41 Freeze protection sensor fault Part replacement
51 Inlet water temperature thermistor fault Part replacement
52 Gas valve fault Call a pro
54 Exhaust gas temperature too high Call a pro
61 Combustion fan motor fault Call a pro
63 Recirculation low flow DIY fix
65 Water flow control valve fault Part replacement
70 PC board fault Call a pro
71 Gas solenoid valve fault Call a pro
72 Flame rod fault Call a pro
FF Maintenance performed marker DIY fix
SS Service soon reminder DIY fix