The widest model list on this site, and the one where the model number matters most. **NC199 with one C is here; NCC199 with two is a different series with a different table**, and Noritz prints them on facing pages of the same manual. Two codes on this table belong to the commercial ASME models alone — Noritz marks 21 and 56 "For NC380-SV-ASME / N-1321M-ASME only", so if you have an NR98 or an NR111 they are not yours and should not be on your list at all. This range has no condensate neutralizer and therefore none of the neutralizer codes its NCC199 sibling carries, and it adds a flow sensor code, 41, that the sibling does not have. Codes appear with an "F" in front when they come from the secondary unit of a quick-connect multi-system.

Models covered: NR98-SV, NR98-OD, NR98-DVC, NC199-OD, NC199-DVC, N-0751M-OD, N-0751M-DV, N-0751M-DVC, NR111-SV, NR111-OD, NR111-DV, NC250-SV-ASME, NC250-DV-ASME, N-0931M-OD, N-0931M-DV, NC380-SV-ASME, N-1321M-ASME

Not your models? Check the model-number decoder before you read the table below — the code numbers repeat across series and the meanings do not.

Code Error Verdict
10 Combustion fault, BTU drop Call a pro
11 Ignition failure Call a pro
12 Flame rod does not detect flame Call a pro
14 Thermal fuse triggered Call a pro
16 Abnormally high output temperature Call a pro
20 High limit switch triggered Call a pro
21 Pressure switch triggered Call a pro
30 Air inlet thermistor fault Part replacement
31 Inlet thermistor fault Part replacement
32 Outlet thermistor fault Part replacement
33 Heat exchanger thermistor fault Part replacement
41 Flow sensor fault Part replacement
56 Multi-system CCP valve fault Part replacement
59 Heat exchanger flow fault DIY fix
61 Fan motor fault Call a pro
65 Main flow control valve fault Part replacement
66 Bypass flow control valve fault Part replacement
70 Circuit board fault Part replacement
71 Gas solenoid valve drive circuit fault Call a pro
72 Flame rod circuit fault Call a pro
73 Circuit board setting fault Call a pro
90 Combustion fault Call a pro
99 Combustion fault, unit shuts off Call a pro
760 Remote controller communication fault Part replacement
F76 Multi-system communication error Part replacement