Noritz NR98 & NR111 Code 59

Heat exchanger flow fault. Noritz puts scale first: check for scale build-up in the heat exchanger, then abnormal combustion, then the flue for blockage or obstruction, then that the flame ignites all the way across the burner. Noritz notes that this code does not appear in the manual's own troubleshooting flowchart.

Also displayed as: F59

DIY fix

The verdict

Descale the unit

Start with the flush, because Noritz does. A scaled heat exchanger restricts flow, which is what this code measures, and a flush is a kit and an afternoon against a heat exchanger that is most of the value of the appliance. If a genuine flush does not clear it, the remaining causes are combustion and the flue, and those are not yours.

Typical cost: $40–$900

US estimate for parts and labor. Prices vary by region and by who does the work — see how we estimate costs.

Advertisement

What the manual says

The meaning above is transcribed from the manufacturer's diagnostic documentation for the NR98 & NR111 — not averaged across the brand.

Source: Noritz Service Manual — NR50 / NR66 / NR71 / NR98 / NCC199 / NRC111 / NR111 / NC380 (Rev. July 2011) (p. 56), read Sep 2026 — the manufacturer's own documentation for this exact series.

What you can safely check

  1. Flush the heat exchanger — our descaling guide covers it end to end.
  2. Check the vent terminal outside while you are at it, since the flue is one of Noritz's causes.
  3. If the code survives a proper flush, book a service call rather than flushing again.
  4. Afterwards, work out your water hardness and set a flushing interval from it.
Advertisement

Code 59 on other Noritz series

The same code number can mean something different on another series — make sure you're reading the page for your exact unit:

Compare Noritz code 59 across all 3 series →

Related parts & guides