Noritz NRCP Eco TOUGH Code Er42

Loose jumper. A jumper on the circuit board is loose. Noritz's description and its remedy say the same thing in different words — "loosed jumper", and "jumper is loose" — with nothing further. This code does not exist on the first-generation NRCP at all. Manual reset.

Also displayed as: 42, E42

Part replacement

The verdict

Replace a part

The shortest entry in the table and one of the cheapest outcomes: a connector on the board that is not seated. It is still inside the cabinet of a gas appliance, so it is a service call, but it should be a quick one.

Typical cost: $100–$400

US estimate for parts and labor. Prices vary by region and by who does the work — see how we estimate costs.

Advertisement

What the manual says

The meaning above is transcribed from the manufacturer's diagnostic documentation for the NRCP Eco TOUGH — not averaged across the brand.

Source: Noritz Service Manual — NRCP1112-DV / NRCP982-DV Eco TOUGH (Rev. 05/19) (p. 58), read Sep 2026 — the manufacturer's own documentation for this exact series.

What you can safely check

  1. Note whether anyone has worked on the unit recently — a jumper works loose most often after a board has been handled.
  2. Book a service call and say it is Er42, a loose jumper. It is a short visit if they know what they are coming for.

Frequently asked questions

My NRCP111 shows Er42 and this page says it should not exist.

Check the model number again. Er42 is documented for the NRCP1112-DV and NRCP982-DV Eco TOUGH only; the NRCP111-DV and NRCP98-DV table has no Er42 and does have an Er46, which this generation drops. The two model numbers differ by one character.

Advertisement

Related parts & guides