Noritz NCC199 & NRC111 Code 93

Neutralizer life cycle has ended. The countdown that started at code 92 has finished. Noritz's instruction is the same — refer to the instructions included with the replacement neutralizer — and the difference is that the appliance no longer considers the cartridge to be doing anything.

Also displayed as: F93

DIY fix

The verdict

Replace a part

Replace the cartridge. It is one of the genuinely homeowner-serviceable parts on a condensing heater — it sits in the condensate line below the unit, not inside the cabinet, and comes apart without touching gas or mains electricity.

Typical cost: $40–$200

US estimate for parts and labor. Prices vary by region and by who does the work — see how we estimate costs.

Advertisement

What the manual says

The meaning above is transcribed from the manufacturer's diagnostic documentation for the NCC199 & NRC111 — not averaged across the brand.

Source: Noritz Service Manual — NR50 / NR66 / NR71 / NR98 / NCC199 / NRC111 / NR111 / NC380 (Rev. July 2011) (p. 55), read Sep 2026 — the manufacturer's own documentation for this exact series.

What you can safely check

  1. Switch the unit off and close the water supply before opening the housing.
  2. Catch what drains out of the cartridge — it is acidic and will mark what it lands on.
  3. Replace the media or the cartridge, following the instructions supplied with it.
  4. Check the drain line downstream while it is off.
  5. If the code stays after a genuine replacement, book a service call — code 29 covers the electrode, and that is inside the unit.