Noritz NCC199 & NRC111 Code 72

Flame rod circuit fault. The unit is detecting a flame when there should not be one. Noritz measures the current from the flame rod with no flame present and checks for a ground fault. It is the reverse of code 12: not failing to see a real flame, but seeing one that is not there.

Also displayed as: F72

Call a pro

The verdict

Call a licensed plumber

A false flame signal is a safety fault, because the logic that decides whether it is safe to open the gas valves depends on that reading being honest.

Typical cost: $150–$700

US estimate for parts and labor. Prices vary by region and by who does the work — see how we estimate costs.

What the manual says

The meaning above is transcribed from the manufacturer's diagnostic documentation for the NCC199 & NRC111 — not averaged across the brand.

Source: Noritz Service Manual — NR50 / NR66 / NR71 / NR98 / NCC199 / NRC111 / NR111 / NC380 (Rev. July 2011) (p. 55), read Sep 2026 — the manufacturer's own documentation for this exact series.

What you can safely check

Before anything else: if you smell gas, stop here, leave, and call your gas utility.

  1. Cut the power for a minute and restore it.
  2. If 72 returns, switch the unit off and leave it off.
  3. Call a licensed professional — a ground fault is one of the two named causes and it needs measuring.

Code 72 on other Noritz series

Other Noritz series report code 72 under the same fault name, but each manual is transcribed separately and they do not read alike:

Compare Noritz code 72 across all 5 series →

Don't confuse this with