Takagi Condensing Code 631

External pump fault. The external pump — a recirculation pump connected to the heater rather than built into it — is not behaving. On installations without one, this code should not appear.

Part replacement

The verdict

Replace a part

Often not a water heater repair at all: an external pump that has lost power, seized, or been switched off produces this. Check the pump before booking anything.

Typical cost: $0–$800

US estimate for parts and labor. Prices vary by region and by who does the work — see how we estimate costs.

Advertisement

What the manual says

The meaning above is transcribed from the manufacturer's diagnostic documentation for the Condensing — not averaged across the brand.

Source: Takagi Condensing Models On-Demand Water Heater Troubleshooting Guide (p. 13), read Aug 2026 — the manufacturer's own documentation for this exact series.

What you can safely check

  1. Find the recirculation pump and check it has power and that you can hear it running.
  2. Check the isolation valves on the recirculation loop are open.
  3. If the pump is dead or the code stays, book a service call.

Frequently asked questions

I do not have a recirculation pump.

Then the heater is configured as though you do. Say that when you call — it is a settings question rather than a hardware one, and it changes where the technician looks.