Rheem Tankless Gas Code 14

Overheat limiter tripped. The OHL — Over Heat Limiter — or the over temperature limit switch has activated. Rheem's note is that when this trips it is normally caused by inadequate or wrong gas supply, which makes it a combustion fault as much as a temperature one.

Call a pro

The verdict

Call a licensed plumber

A safety limiter tripped on a gas appliance. Do not reset repeatedly — the limiter is doing exactly what it exists to do, and Rheem's own first suspicion is the gas supply. Scale in the heat exchanger is the other classic cause.

Typical cost: $150–$1,400

US estimate for parts and labor. Prices vary by region and by who does the work — see how we estimate costs.

Advertisement

What the manual says

The meaning above is transcribed from the manufacturer's diagnostic documentation for the Tankless Gas — not averaged across the brand.

Source: Rheem Tankless Gas Troubleshooting Pocket Manual (SVC820) (p. 50), read Aug 2026 — the manufacturer's own documentation for this exact series.

What you can safely check

Before anything else: if you smell gas, stop here, leave, and call your gas utility.

  1. Turn the unit off and leave it off until it has been checked.
  2. If you smell gas, leave and call your gas utility from outside.
  3. Note when it was last flushed and whether your water is hard.
  4. Note any recent gas work, conversion, or new appliances added to the gas system.

Frequently asked questions

The unit works again after it cools. Is it fixed?

No. A limiter that resets itself after cooling will trip again as soon as the same conditions return. What changed is the temperature, not the cause.

Advertisement

Related parts & guides